Lateral Connector M140 – for connecting thin walled lateral pipes to concrete main sewers

The Lateral Connector M140 connects thin walled pipes (e.g. plastic, cast iron, etc.) to concrete main sewers.

The design of the Lateral Connector M140 allows cutting the connector to the length of the main sewer wall thickness.

PHONE Sales & Technical-Team
+49 2234 928 03-0
Description
Lateral Connector M140
Technical Specification

Lateral Connector M140 for connecting thin walled lateral pipes to existing concrete main sewers, covering a wall thickness of maximum 140 mm.

Manufacturer:

MÜCHER DICHTUNGEN®, 50226 Frechen, T +49 2234 928 03-0, F -55

Pressure Tightness:

0.5 bar

Jetting Resistance:

120 bar

Sealing Material:

EPDM rubber according to DIN EN 681-1

Temperature Resistance:

-40°C to +120°C, temporary max. temperature +160°C

Standard/Approval:

DIN EN 681-1, CE06
LATERAL CONNECTOR M140
Article NumberReferenceOutside Ø
Lateral Pipe
(mm)
Min. Wall Thickness
Main Sewer
(mm)
Core Drill
(mm)
L
Length
(mm)
resistant to
(bar)
Weight
(kg)
32240100RRD M140 DN 100 PVC110451221550,50,4
32240125RRD M140 DN 125 PVC125451371550,50,4
32240150RRD M140 DN 150 PVC160451721550,50,6
32240200RRD M140 DN 200 PVC200452121550,50,7
32240250RRD M140 DN 250 PVC250452621550,50,9
32240300RRD M140 DN 300 PVC315453271550,51,0
32240400RRD M140 DN 400 PVC400454121550,51,1
32140100RRD M140 DN 100 SML110451221550,50,4
32140125RRD M140 DN 125 SML135451471550,50,5
32140150RRD M140 DN 150 SML160451721550,50,6
32440100RRD M140 DN 100 GGG118451301550,50,4
32440150RRD M140 DN 150 GGG170451821550,50,6
  • Drill and clean hole 90° to pipe axis.
    Drill and clean hole 90° to pipe axis.
  • Cut M140 to length of wall thickness and insert M140 into main sewer.
    Cut M140 to length of wall thickness and insert M140 into main sewer.
  • Apply lubricant to lateral plain end and push lateral into M140.
    Apply lubricant to lateral plain end and push lateral into M140.